Categories
Telecommunications & Media
Discover easy-to-use Telecommunication & Media templates and training courses for distribution, compliance check, and more. Use them to gain practical knowledge, streamline your work, and stay on top of industry best practices. Customize these resources to fit your needs and excel in the Telecommunication & Media industry with confidence.
- Template
Satellite Rope Job Information Checklist
This Satellite Rope Job Info checklist helps technicians plan and document satellite dish work that requires rope access. Capture job details such as location, job number, technician, date, and address. Add photos of the dish and access points, sketch anchor locations, and outline the method including rig setup, hatch access, and rope layout so another tech can follow the plan. Confirm customer awareness of weather dependencies, appointment timing, drilling or access requirements, and estimated job duration. Record other notes like parking or boosters and obtain a signature for sign-off.
by Fraser Hobbs, from the CommunityDownloads: 20+Get - Template
Inspeções internas DTC Boavista
Checklist de inspeções internas para um centro de telecomunicações, cobrindo construção civil, eletricidade AC e DC, tomadas de energia/dados/voz, UPS, climatização (UCC, ventiloconvectores, VRV, chillers, freecooling, humidificadores), grelhas e condutas, ventiladores, UTAs, registos corta-fogo, unidades condensadoras e splits. Inclui verificação de sistemas de segurança: deteção e extinção de incêndio (CDI, CAEI, CDA, FE-13, CO2), extintores, carretéis, sinalização de emergência, fontes de alimentação, painéis ótico-acústicos, selagens corta-fogo, deteção de hidrogénio e central de inundação. Regista consumos e medições em UPS, QEA, POWER DC/LTM e horas de compressores UCC, com campos para observações, fotos, data e responsável pela inspeção.
by Manuel Oliveira, from the CommunityDownloads: 20+Get - Template
Openreach A55 Network Adjustment Checklist
This Openreach A55 checklist helps telecom field teams scope and document network adjustments. It captures PIA NOI number, site address and contacts, completion date, and local authority. The form guides assessment of overhead issues, alternative routes, pole equipment and dimensions, DP number, pole size and class, existing and forecast wires, side load and private property considerations, and pole top consolidation. It includes chamber location and type, surface type, traffic management needs, bores, X and Y coordinates, photos, blockages and distances, duct sections, additional capacity, potential cable recovery, evidence of damage, OR portal screenshots, grid references, and signature.
by Mick Warden, from the CommunityDownloads: 20+Get - Template
FTTP No Power Repair Checklist (Update V.2)
This FTTP No Power Repair Checklist guides field technicians through diagnosing and fixing loss-of-light issues on fiber-to-the-premises installations. Steps include confirming the correct FDH, checking power at the CSP and FDP, using a visual red light test, identifying incorrect FDH locations, documenting photos, verifying splitter output, tracing ASN feed, and splicing to a live fiber where required. It emphasizes secure closures, proper labeling, and evidence capture to restore service and differentiate customer faults from network build issues.
by Leon Clarke, from the CommunityDownloads: 20+Get - Template
Clearvision HSEQ Audit Template for Telecom Sites
This HSEQ audit template is designed for telecom fibre installation and field work. It guides auditors through pre-start risk assessment, site induction, PPE checks, traffic management, and health, safety and environmental compliance. It includes controls for utilities locating, hazardous chemicals, MSDS, first aid and fire equipment. Quality sections cover fibre and conduit runs, FTP and ITP installation, ONT and cable management, VoIP integration, trenching and reinstatement, site and vehicle tidiness, and evidence capture. Record non-compliances, corrective actions, coaching, and final site safety status.
by Rhyan Reynon, from the CommunityDownloads: 20+Get - Template
Inspecções de Infraestruturas de Telecomunicações
Modelo de inspeções para infraestruturas de telecomunicações, abrangendo construção civil, eletricidade AC/DC, iluminação e tomadas, AVAC (UCC, ventilação, UTA/UTAN, VRV, splits, humidificadores), segurança contra incêndio (CDI, CAEI, CDA, extinção fixa FE-13/CO2, extintores, carretéis, sinalética, alarmes), fontes de alimentação e baterias, UPS, geradores e posto de transformação. Inclui registo de consumos (EDP, água), medições de tensão/corrente em sistemas power DC/AC, contadores de horas e arranques, freecooling e chillers, bem como observações, fotos, data/hora e validação do inspetor.
by Manuel Oliveira, from the CommunityDownloads: 20+Get - Template
VSZ Copper Reactive Maintenance Calibrated Audit
Use this calibrated audit to evaluate VSZ copper reactive maintenance in the field. Sections cover admin compliance, correct codes, accurate customer and cable pair records, customer communication and service demonstration, general workmanship including ground reinstatement and site tidiness, and network elements such as exchange, cabinet, terminals, service lead labeling, and ETP installation with sealed penetrations. Ideal for supervisors conducting quality checks and standardizing reactive maintenance across copper networks.
by Andrew Goodman, from the CommunityDownloads: 20+Get - Template
FTTH Phase 1.5/2 Power Test Walk-Off Report
This FTTH build walk-off report helps teams record Phase 1.5 and Phase 2 power testing for fiber deployments. Document IOLM Phase 1 results, local cabling checks, and splitter installation at distribution points, then power test to one in eight through splitters using a local generator where required. Capture comms cabinet setup, patch leads fitted at split panels, and photo evidence. Note where PIA is pending, and confirm responsibilities for final patching and second-stage testing. Complete all fields for a thorough handover.
by Nelio Goncalves, from the CommunityDownloads: 20+Get - Template
Customer Connections PIC Template
This PIC template supports engineers performing fiber customer connections. It guides photo capture and verification steps including node open and labeling, power tests, fiber wrapped in tray with labels, Hyperoptic label at cable entry, rope left in all chambers and toby box, chamber cleanliness and closure, and cable coil tests at the property. It also prompts for the number of chambers worked on, challenges encountered, meters of fiber used, A55 submission, and CIV reference numbers. Use it to standardize documentation for underground fiber cabling and customer activation.
by Saif Maljee, from the CommunityDownloads: 20+Get - Template
Virgin Media Cable Conditioning Survey v3.1
This template supports cable conditioning and network assessment of Virgin Media MDU installations over 18m that were cabled before 2015. It guides surveyors through external and internal cabling checks, ensuring cables and trunking are secure, entry holes are properly sealed, and firestopping meets current standards. It captures access and egress risks, building details, floor and property counts, and the condition and safety of lockboxes and distribution points. The survey records photographic evidence, notes unauthorized works, and classifies remedial priorities from P1 critical to P6 restricted. A final summary consolidates hazards, affected areas, and recommended remedial works, with an SOR section to quantify required materials and labor.
by Nelio Goncalves, from the CommunityDownloads: 20+Get - Template
LTE Installation Checklist After Installation
This LTE installation checklist guides technicians through post-install checks for indoor and outdoor components. Verify baseband mounting and grounding, SPD and DC connections, SFP mappings for 800 and 1800 bands, and proper labeling of fiber and TRM cables. Capture photos of cabinets, SPDs, PDUs, and baseband. Outdoors, confirm RRU installation and earthing, isolation and routing of DC and fiber on clamps, correct jumper connections to 800 and 1800 antenna ports, and secure cable trays. Label RRUs, fiber, and DC leads. Record NOC handover details, remarks, and supporting images. Use this checklist to standardize quality, safety, and documentation after install.
by Powertech Ericsson, from the CommunityDownloads: 20+Get - Template
Visionstream Layer2 & Access Quality Audit Sheet
Use this telecom quality audit checklist to verify Layer2 and access build work across exchange environments. Assess safety and work area controls, standards compliance, and correct use of CNSP-approved materials. Review exchange equipment, MDF labeling and jumper management, OFDF fibre handling, bend radius, cleaning, and laser safety. Confirm records integrity, OTDR traces, compliance certificates, GPON rack setup, alarms, and complex services. Validate cable removal, earthing, and tidy handover to Chorus.
by Mel Dawson, from the CommunityDownloads: 20+Get - Template
Cinema Installation Sign Off Checklist (SCCI)
This SCCI cinema sign off checklist helps technicians document AV and broadcast installation details at site handover. Capture site name and address, completion date, and engineer details. Record satellite dish placement and access, Freeview or Freesat antenna installation, cabling types and routes, and the number of connections. Confirm receiver locations and site readiness, and attach photos of dishes, antennas, receivers, and cable runs. Finish with client and engineer names and signatures to formally sign off the installation.
by gary peacock, from the CommunityDownloads: 20+Get - Template
Build and Connect Scope
This Build and Connect Scope template supports telecommunications network installations, particularly fiber-to-premises work. Capture service order details, premises type, and retail service provider, then assess boundary access and civil works such as trenching, thrusting, conduit, and paving. Document total run measurements from drop-off to ETP, internal access, external cabling, and meters of conduit or capping. Specify internal cabling methods, integrate phone lines, note technician install time, and record the ONT location. The form also collects end-user consent and signatures to authorize works and acknowledges potential impacts on monitored alarms and existing telecom services.
by Sam Fronczek, from the CommunityDownloads: 20+Get - Template
ACM Pit Removal Photo Audit Checklist
This wideband photo audit checklist supports safe, compliant ACM pit removal and installation on telecommunications sites. It guides field teams to capture clear photographic evidence across five stages: community engagement, identification and certificates, site setup, pit installation, and completion. Document Class B asbestos licenses, supervisor certification, worker ID and white cards, PPE use, exclusion zones, signage, traffic control, waste packaging and carriage, and disposal dockets. Verify pit sizing, bedding, alignment, gaskets, plugs, lids, and reinstatement. Designed to help contractors meet Telstra and state requirements and streamline audit compilation and sharing.
by Paul McBurney, from the CommunityDownloads: 20+Get - Template
Fibre Business Connection Reschedule
This template helps telecommunications teams document and manage fibre business connection reschedules. Capture service order details, RNC reason codes, customer contact, completed work, next steps, and proposed dates to coordinate field managers, civils, build crews, power poles, Chorus, and RSP stakeholders.
by Joshua van Rooyen, from the CommunityDownloads: 20+Get - Template
Job Cancellation Report
This Job Cancellation Report template helps field teams in Build and Connect projects record service numbers and job addresses, customer information, scoper notes, and proof of attendance. Capture customer and scoper signatures to document site visits and support cancellation decisions.
by Optrek Solutions, from the CommunityDownloads: 20+Get - Template
Site Manager FFP Completion Certification
This checklist helps site managers certify fibre footprint completion before handover to Chorus. Confirm all civil and fibre NCRs are rectified, verify RMA depth requirements, and ensure as-built documentation is uploaded and checked in Viscore. Review CPA, GPON, OFDF, and FOG plans, and confirm ONT testing and splitter installation across every FFP. Use this audit to validate compliance and readiness for site signoff.
by Mel Dawson, from the CommunityDownloads: 20+Get - Template
RCM Store Visit Checklist 2022
Conduct effective retail telecom store audits with this RCM store visit checklist. Review store standards and the end to end customer journey, verify Pronto usage, and monitor complaints and NPS insights. Assess commercial performance across core KPIs including pay monthly, upgrades, home broadband, full fibre, hybrid, and attach rates such as BAN, SMART mix, insurance, and TV. Capture people management actions by checking monthly reviews for advisors and assistant managers and ensuring raising contribution plans are in place.
by Bobby Greasley, from the CommunityDownloads: 20+Get - Template
Data Cable Inspection and Check Sheet
This data cable inspection and check sheet helps teams verify the quality and safety of installed data cabling. It guides technicians through visual checks for damage, correct tagging, and confirmation of cable type and size against schedules. It covers proper terminations at source and destination, adequate fixing, support, and protection, plus correct gland installation. The checklist includes continuity testing steps using a transmitter and receiver, ensuring lights operate in sequence to confirm cable integrity. It concludes with as-built drawing markups, fitness-for-service confirmation, comments, and sign-off for clear closeout documentation.
by Diarmuid O'Donovan, from the CommunityDownloads: 20+Get - Template
Firehawk Site Audit Checklist
Use this Firehawk site audit checklist to assess telecommunications tower sites. Capture tower details including type, height, and anchor condition, plus battery box power source and voltage. Record solar panel counts and wattage where applicable. Document equipment such as camera type, HD or analog links, wind generator, navigation lights, and on-site security systems. Evaluate the surrounding area for condition and access, attach photos, and add notes to support compliance and maintenance decisions. Version 1.1 sample from the SafetyCulture Public Library.
by Tristan Wilson, from the CommunityDownloads: 20+Get - Template
ITS Box-to-Box Route Inspection Checklist
Use this ITS box-to-box route inspection template to plan and document underground telecom duct routes between chambers and boxes. Annotate portal maps, number chambers, select box types, and record section lengths and condition. Capture required photos of chamber setup, roller bar and GDU, roped ducts, and overall locations. Note blockages, track or desilting needs, and assets such as manholes, poles, and lids. This checklist standardizes field data collection for fibre or copper network builds and maintenance.
by SML Office, from the CommunityDownloads: 20+Get - Template
ISAM Exchange Site Photo Audit Checklist
This ISAM exchange site photo audit checklist guides installers and auditors through a comprehensive photographic verification of telecom rack deployments at exchange facilities. Sections cover superstructure assembly, rack positioning and integrity, earthing and isolation, fibre labelling, power feeds to ISAM, subrack installation, MDF blocks, line and PLT cabling, and labeling standards. Use the checklist to confirm correct components, routing, bend radius, card placement, and safety compliance, with references to relevant design packs and technical manuals. Capture clear, legible photos for each item and record project and site details for traceability.
by Edward Hu, from the CommunityDownloads: 20+Get - Template
BT WiFi Installation Sign Off for Costa Coffee
Use this installation sign off checklist to complete BT WiFi deployments at Costa Coffee sites. Capture site details, cabling and access point locations, speed test results and photo evidence. Document BT Smart Hub placement, 4G backup, power distribution unit, network switch, power over Ethernet and patch cabling. Verify labeling, trunking and tidy cabling. Submit images of access points, speed tests, landing page and hub management to BT, and send SCR copies to SCCI. Record snagging items and resolutions. Collect customer and engineer sign offs, visit times and the SCCI clearcode to close the job.
by Andy Holland, from the CommunityDownloads: 20+Get
