This construction QA checklist supports inspection of party wall drylining for South Thamesmead Phase II. It guides supervisors and subcontractors through checks on bottom and deep tracks, stud spacing and deflection gaps, fire strips and mastic, identification of wall types and junctions, cavity insulation (including 35 kg/m3 mineral and APR insulation), and 90/120 minute fire-rated partitions. It includes verification of IR01/IR02/IR03 riser and smoke shaft walls, timber studs at door jambs, security mesh, screw spacing to a 300 mm maximum, service fixing plasterboard strips, and screed shutters. The checklist emphasizes use of British Gypsum materials, requires photo evidence for key steps, and confirms areas are left clean, with sign-offs from contractor and client.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.