Quality assurance checklist for party wall drylining on South Thamesmead Phase II. Verify correct installation of bottom and deep tracks, deflection allowances, firestrips or mastic, and stud spacing. Check fixing plates, set-out compliance, party wall junctions, cavity insulation including APR and 35 kg per m3 mineral wool, and fire rated walls at 90 or 120 minutes. Identify IR01 to IR03 riser or smoke shaft wall types, timber studs to door jambs, security mesh, and screw spacing at 300 mm. Confirm service fixing plasterboard strips, screed shutters, use of British Gypsum materials, site cleanliness, and capture photo evidence and signatures.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.