This HVAC inspection checklist is designed for two units and covers both condensers and furnaces. Record equipment make, model, voltage, and refrigerant type; verify minimum and maximum fuse ratings; check and adjust thermostats; assess condenser coil condition; capture condenser fan and compressor amps; note refrigerant levels and pressures; inspect wiring, contactors, capacitors, relays, and the outdoor disconnect; confirm suction line insulation and secured panels. For furnaces, inspect filters, overall condition, and potential gas leaks; test heater operation and electrical components; check air to fuel ratio, return and supply plenums, secondary pan, and evaporator cabinet for oil stains; evaluate installation quality and duct leaks. Use this template to standardize preventive maintenance and document findings.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.