This inspection and test plan checklist supports construction of the concrete deck and stairs for the NQBP Booster Pump Station. It guides teams through setout against the latest IFC drawings, installation of formwork and falsework, and placement of correct reinforcement including stair steel and deck penetrations. It records concrete strength and slump, pumping needs, and water added. A pre pour hold point enables consultant review and sign off. The workflow then covers pouring, vibration, application of surface treatments, machine trowel finish, curing, stripping formwork, and cleaning. Finally, it captures photo evidence and signatures for contractor and consultant completion.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.