Panelised Wall and Floor Cassettes Install Checklist
by Jacob Goldsmith, from the Community
This construction checklist guides the installation and QA of panelised timber wall and floor cassettes. It covers pre-start requirements, SWMS, site-specific hazards, site access, and amenities. Verify tools and equipment, PPE, and MSDS. Inspect slab dimensions, placement of preinstalled beams, and Partiwall. Check intermediate floor cassettes for correct fixings and connections, square and level alignment, and install safety rails and void platforms. Confirm walls, floors, and roof elements are square, level, and plumb, braces are secure, uninstalled elements are made safe, photos are taken for records, and the site is cleaned.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.