This hop up permit and inspection checklist helps construction teams control low level access work. Record site details, subcontractor and preparer, list operators using hop ups, and specify the exact location of use. Confirm the 600 x 600 hop up and note if safer means of access are available, including why alternatives are not practical. Perform thorough pre use checks for wear, cracks, contamination, and inspect fittings, rivets, and welding. Verify all parts are intact and free from decay or corrosion, and check hooks, catches, feet, caps, and hinges for condition and function. Confirm suitability for use, ensure the scaffold tag has been signed within seven days by a PASMA trained person, and upload the PASMA certificate. Finish with sign off and signatures to authorize safe use.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.