This IDI Shaftwall Quality Control checklist supports QAQC inspections for shaftwall installations. It helps inspectors verify updated drawings, RFIs, and specs; confirm MEP riser inspections are signed off; and check fire damper framing per manufacturer data. It covers verifying studs, drywall, and shaftliner materials per plans; bottom track attachment; staggered liner panel joints; liner panel top set 1 inch below top track; liners fastened to J-runners; mineral wool installed for firestopping; and minimum 1/8 inch firestopping spray thickness. It also prompts cleanup of cartons and scrap, a site walk with the GC superintendent, comments, and final sign-off.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.