Barnard Hand Epoxy Coating Application Checklist
by Jarek Arneson, from the Community
This checklist helps crews prepare and verify conditions before hand applying epoxy coatings. It covers operator qualifications and span of control, calibration checks for psychrometer and DFT meter, and per-feature verification of key parameters. Users confirm humidity and ambient temperature limits, anchor profile, and pipe surface temperature, then measure wet and dry film thickness within specified ranges for common products such as Protal 7200, 3M 323, and Devgrip 238. The checklist also includes holiday detection at appropriate voltage, documentation of repairs, visual inspection, photo attachment, and recording weld or station details to ensure coating quality and compliance.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.