Use this audit protocol to verify the electrical isolation of steel pipeline casings in line with MG AP CP3.031. The checklist guides crews through spot potential measurements, anode disconnection, and ON OFF readings with a current interrupter at the nearest cathodic protection unit. It prompts checks for casing to pipe potential differences at 200 mV and 5 mV thresholds, procedures to confirm isolation or identify shorts, and steps to calculate, record, and report the location of any short for excavation and repair. Final sections cover reconnection of anodes, site cleanup, safety, and sign off.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.