Solar PV Upperstructure Installation Inspection

by Roy de Bie, from the Community

0
Get this template

Use this inspection checklist to confirm correct installation of solar PV upper structures. Verify structural condition, bolt torque within manufacturer ranges, design compliance, and alignment of columns, beams, and tables. Check height differences between east and west tables, inclination around 10 degrees plus or minus 1 degree using a calibrated digital level, and ensure no stress on joints. Inspect for corrosion, and confirm any drilled frames are treated properly. Requires calibrated torque wrench and review of drawings.

With SafetyCulture you can

Digitize any process, procedure or policy
Eliminate mistakes made by paper-based processes
Create and share professional reports instantly
Confirm accountability and compliance with a digital log

With SafetyCulture you can

Digitize any process, procedure or policy
Eliminate mistakes made by paper-based processes
Create and share professional reports instantly
Confirm accountability and compliance with a digital log

About author

This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.