Use this wet area inspection template to assess bathrooms, laundries, and toilets before waterproofing. Verify substrate condition and falls, primer application, membrane type, and bond breaker selection. Check shower angle or water stop, drainage openings, and that screeds are sound with required fall ratio of 1:100. Confirm priming of PVC penetrations, bandaging or fillet joints at wall and floor junctions, and sealing around tap and toilet penetrations. Ensure membrane extends into the drainage flange, covers door jambs, and meets height requirements around showers and baths. Record micrometer thickness readings at a minimum of five points and capture photo evidence of works before and after. This checklist helps document compliance and quality for wet areas.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.