This roofing quality inspection checklist supports QA on tile and slate construction. It covers underlay integrity and placement, rafter jointing and batten gauging, tile fixing specifications, ridge and hip fixings, dry and wet verge fastenings, adequate coverage around Velux windows and dormers, valley and eaves detailing with lead saddles, soaker length, perimeter nailing on plain tiles, mortar finish standards, and correct installation of vent tiles or slates. Leadwork checks include stepped flashing under trays, cover flashings, acceptable mastic application, and patination oil treatment. Housekeeping items include scaffold and work area cleanliness and material storage. Tile hanging requirements include nailed Winchester cuts and double nailing. The template ends with inspection sign-off for accountability.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.