This mobile tower scaffold checklist helps crews verify safe setup and use of access towers. It covers inspection timing first use, after alterations or events, and at intervals not exceeding 7 days. Items include ground conditions, castors or base plates and brakes, adjustable legs for leveling only, tower levelness, stabilisers size and position, bracing pattern and hooks, handrails and mid guards, frame interlocks, platform placement and widths, trap door orientation, wind locks, toe boards, tie in methods, maximum permitted loads, power line clearances, work area cordons, and signage for incomplete towers. Capture site details, photos, PASMA references, and complete sign off with a tower tag reference.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.