This exterior framing QAQC checklist supports site inspectors and crews in verifying that framing work meets plans, specifications, and manufacturer requirements. It covers anchorage of bottom and deflection tracks, plumb alignment, correct stud gauge and installation, allowable stud-to-track gaps, and proper clip and accessory placement. Inspectors confirm wall stud plumbness, control and expansion joint layout and framing, temporary and permanent bracing, and backing for reveals, terminations, and fixtures. The checklist includes verification of framed openings for doors, windows, and grilles; insulation at double studs and headers; horizontal bridging; painted stud welds and completed welding; correct screw patterns; and absence of knockouts near tracks. It concludes with site cleanup and a walkthrough with the general contractor superintendent.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.