Horizontal Fire Barrier in Terracotta Rainscreen
by Martin Coupe, from the Community
Use this quality assurance checklist to inspect horizontal fire barriers within terracotta rainscreen cavities. Verify location to approved drawings, correct Siderise brackets and required folds over the intumescent strip of 15 mm, maintain a ventilation gap of 25 mm plus or minus 3 mm, apply foil tape to all joints and abutments, and keep the area clean. Capture photos and notes, assign corrective actions with priorities and due dates, and obtain installer, A2O, and client signatures. Export reports as PDF, Word, Excel, or a web link.
With SafetyCulture you can
With SafetyCulture you can
About author
This community page makes available free workplace checklists and templates created by other users within the SafetyCulture community. SafetyCulture has re-published this content and where possible, has credited the original author. SafetyCulture has not verified the accuracy, reliability or suitability of any community content. You agree that your use of any of this content is in accordance with SafetyCulture’s Terms and Conditions.